1How the pressure tank size calculator works
The pressure tank size calculator first finds the drawdown you need: pump GPM times the minimum run time. Most pump makers want at least one minute of running per start so the motor can cool. A 10 GPM pump therefore needs 10 gallons of drawdown.
Then it divides by the drawdown factor, the share of the tank that is usable water between cut-in and cut-out. The factor comes from Boyle's law with the air charge set 2 psi below cut-in, which is how manufacturers rate their tanks.
| Switch setting | Air precharge | Usable share of tank |
|---|---|---|
| 20/40 psi | 18 psi | 0.34 |
| 30/50 psi | 28 psi | 0.30 |
| 40/60 psi | 38 psi | 0.26 |
2Reading the result
Tanks are sold by total volume, so pick the next size up. A 10 GPM pump at 40/60 psi needs about 39 gallons of tank. Two smaller tanks piped together add up the same way. A constant-pressure pump with a variable speed drive needs only a small tank; follow that pump's manual instead.
Sources
- WellMate inline pressure tank data sheet, Pentair · accessed Nov 22, 2026
- How to calculate and control pressure tank drawdown, The Driller · accessed Nov 22, 2026