septicwellguide Sizing tools

Pressure tank size calculator

Enter the pump's flow rate and your pressure switch setting to get the total tank size that keeps the pump running at least one minute per cycle.

–

1How the pressure tank size calculator works

The pressure tank size calculator first finds the drawdown you need: pump GPM times the minimum run time. Most pump makers want at least one minute of running per start so the motor can cool. A 10 GPM pump therefore needs 10 gallons of drawdown.

Then it divides by the drawdown factor, the share of the tank that is usable water between cut-in and cut-out. The factor comes from Boyle's law with the air charge set 2 psi below cut-in, which is how manufacturers rate their tanks.

Drawdown factor by switch setting
Switch settingAir prechargeUsable share of tank
20/40 psi18 psi0.34
30/50 psi28 psi0.30
40/60 psi38 psi0.26

2Reading the result

Tanks are sold by total volume, so pick the next size up. A 10 GPM pump at 40/60 psi needs about 39 gallons of tank. Two smaller tanks piped together add up the same way. A constant-pressure pump with a variable speed drive needs only a small tank; follow that pump's manual instead.

Sources

  1. WellMate inline pressure tank data sheet, Pentair · accessed Nov 22, 2026
  2. How to calculate and control pressure tank drawdown, The Driller · accessed Nov 22, 2026