septicwellguide Sizing tools

Septic tank size calculator

Pick the number of bedrooms and see the minimum tank size five state codes require. Codes size tanks by bedrooms, not bathrooms or people.

–
Minimum by state code
StateMinimum tank

1How this septic tank size calculator works

The septic tank size calculator looks up your bedroom count in five published state tables and shows the smallest and largest minimum. Codes count bedrooms because a bedroom is the best predictor of how many people will live in the house over the tank's life, even if you live there alone today.

Minimum tank size in five state codes
BedroomsMinnesotaNevadaVirginiaGeorgiaWashington
1–21,0001,0007501,0001,000
31,0001,0009001,0001,000
41,5001,2001,2001,0001,000
51,5001,5001,5001,2501,250
62,0001,500–1,5001,500

Values are gallons of liquid capacity. Virginia's table stops at five bedrooms in the calculator because larger homes are sized case by case.

2What the number does not cover

  • Garbage disposal. Some counties require a larger tank or a second compartment when the house has one.
  • Pump tanks and alternative systems. Mound, aerobic and pressure-dosed systems use extra tanks sized by the designer.
  • Local rules. Counties can set bigger minimums than the state. Your permit sets the final size.

Sources

  1. Minnesota Rules 7080.1930, septic tank capacity, Minnesota Legislature · accessed Nov 22, 2026
  2. Nevada Administrative Code 444.8306, via Cornell LII · accessed Nov 22, 2026
  3. Virginia 12VAC5-610-815, Virginia Law · accessed Nov 22, 2026
  4. Washington WAC 246-272A-0232, Washington State Legislature · accessed Nov 22, 2026
  5. Georgia onsite sewage manual, section J, Georgia Department of Public Health · accessed Nov 22, 2026